ALL CLEAR โ Tidak Ada Alarm Kebakaran Aktif
32
Zona Normal
0
Zona Alarm
1
Trouble
4/4
FM-200 Ready
3/3
VESDA Clear
FACP โ Zona Proteksi (32 zona)
Notifier NFS-320 ยท โ
Z01 - Server Hall A
Normal
Z02 - Server Hall B
Normal
Z03 - Cooling Room
Normal
Z04 - UPS Room A
Normal
Z05 - UPS Room B
Normal
Z06 - Genset Room
Normal
Z07 - NOC Room
Normal
Z08 - Storage Room
Trouble
+24 zona lainnya ยท semua Normal ยท Lihat semua โ
FM-200 Status
FM-SH-A
Server Hall A
FM-SH-B
Server Hall B
FM-UPS-A
UPS Room A
FM-UPS-B
UPS Room B
VESDA Status
VESDA-SH-A
0.008 %/m
VESDA-SH-B
0.005 %/m
VESDA-UPS-A
0.012 %/m
Event Terkini
| Waktu | Zona | Sistem | Event | Durasi | Status |
|---|---|---|---|---|---|
| 2026-03-01 03:22 | Z08 - Storage | FACP | Panel Trouble - Detector Disconnect | Ongoing | Trouble |
| 2026-02-20 14:15 | Z01 - SH-A | VESDA | Authorized Test - Aerosol Commissioning | 12 menit | Resolved |
| 2026-02-10 09:00 | All Zones | FACP | Monthly Test - Panel Self Test | 5 menit | Resolved |
| 2026-01-28 19:42 | Z04 - UPS-A | FACP | False Alarm - Dust Particle | 3 menit | Resolved |
32
Total Zona
Notifier NFS-320
31
Zona Normal
1
Trouble
Z08 - Storage Room
0
Alarm Aktif
0
Disabled
Trouble: Z08 โ Storage Room
Detector disconnect sejak 2026-03-01 03:22 ยท Teknisi telah dinotifikasi ยท Estimasi perbaikan: hari ini
Semua Zona (32)
Detail Zona per Area
| ID Zona | Nama Zona | Area | Lantai | Detector | Panel | Status |
|---|---|---|---|---|---|---|
| Z01 | Server Hall A - Row A/B | Data Hall | 1 | 8 Smoke + 2 Heat | Panel-01 | Normal |
| Z02 | Server Hall B - Row C/D | Data Hall | 1 | 8 Smoke + 2 Heat | Panel-01 | Normal |
| Z03 | Cooling Room CRAC | Mechanical | 1 | 4 Smoke + 1 Heat | Panel-01 | Normal |
| Z04 | UPS Room A | Electrical | 1 | 6 Smoke + 2 Heat | Panel-01 | Normal |
| Z05 | UPS Room B | Electrical | 1 | 6 Smoke + 2 Heat | Panel-01 | Normal |
| Z06 | Generator Room | Mechanical | B1 | 4 Smoke + 4 Heat | Panel-02 | Normal |
| Z07 | NOC Room | Office | 1 | 4 Smoke | Panel-01 | Normal |
| Z08 | Storage Room | Support | 1 | 4 Smoke (-1 disconnect) | Panel-01 | Trouble |
| +24 zona lainnya ยท semua Normal | ||||||
3
Unit VESDA
Xtralis VESDA-E VEA
3
Status Clear
0.008
Max Level (%/m)
SH-A ยท Threshold: 0.05
364
Hari Bebas Event
VESDA-SH-A โ Server Hall A
ClearXtralis VESDA-E VEA ยท 4 Sampling Pipe
Level Deteksi per Pipe
Pipe 1 โ Row A (top)0.008 %/m
Pipe 2 โ Row A (mid)0.006 %/m
Pipe 3 โ Row B (top)0.007 %/m
Pipe 4 โ Row B (mid)0.005 %/m
Threshold & Konfigurasi
Alert Level0.050 %/m
Action Level0.100 %/m
Fire 10.200 %/m
Fire 20.500 %/m
Inspeksi terakhir: 10 Feb 2026
Inspeksi berikutnya: 10 Mei 2026
VESDA-SH-B โ Server Hall B
ClearXtralis VESDA-E VEA ยท 4 Sampling Pipe
Pipe 1 โ Row C (top)0.005 %/m
Pipe 2 โ Row C (mid)0.004 %/m
Pipe 3 โ Row D (top)0.006 %/m
Pipe 4 โ Row D (mid)0.003 %/m
VESDA-UPS-A โ UPS Room A
ClearXtralis VESDA-E VEA ยท 2 Sampling Pipe
Pipe 1 โ Battery Area0.012 %/m
Pipe 2 โ UPS Inverter0.009 %/m
UPS room memiliki threshold lebih sensitif: Alert 0.03 %/m karena risiko off-gassing baterai
Trend Level Asap 24 Jam Terakhir
Semua Sistem FM-200 Siap โ Ready to Discharge
4 sistem aktif ยท Tekanan semua silinder normal ยท Tidak ada riwayat discharge darurat
FM-SH-A
Server Hall A ยท Novec 1230
TEKANAN SILINDER
42.1 bar
AGENT WEIGHT
48.2 kg
LUAS AREA
250 mยฒ
KONSENTRASI
6.25%
Tekanan Silinder42.1 / 45 bar
Inspeksi terakhir: 15 Jan 2026
Inspeksi berikutnya: 15 Apr 2026
Mode: Automatic
FM-SH-B
Server Hall B ยท Novec 1230
TEKANAN SILINDER
43.5 bar
AGENT WEIGHT
48.2 kg
LUAS AREA
250 mยฒ
KONSENTRASI
6.25%
Tekanan Silinder43.5 / 45 bar
Inspeksi terakhir: 15 Jan 2026
Inspeksi berikutnya: 15 Apr 2026
Mode: Automatic
FM-UPS-A
UPS Room A ยท Novec 1230
TEKANAN SILINDER
41.8 bar
AGENT WEIGHT
32.4 kg
LUAS AREA
120 mยฒ
KONSENTRASI
6.25%
Tekanan Silinder41.8 / 45 bar
Inspeksi terakhir: 15 Jan 2026
Inspeksi berikutnya: 15 Apr 2026
Mode: Automatic
FM-UPS-B
UPS Room B ยท Novec 1230
TEKANAN SILINDER
44.0 bar
AGENT WEIGHT
32.4 kg
LUAS AREA
120 mยฒ
KONSENTRASI
6.25%
Tekanan Silinder44.0 / 45 bar
Inspeksi terakhir: 15 Jan 2026
Inspeksi berikutnya: 15 Apr 2026
Mode: Automatic
Riwayat Discharge & Inspeksi
| Tanggal | Sistem | Tipe | Keterangan | Teknisi | Hasil |
|---|---|---|---|---|---|
| 15 Jan 2026 | Semua | Inspeksi | Quarterly pressure check & weight verification | PT Servochem Indonesia | Pass |
| 15 Okt 2025 | Semua | Inspeksi | Quarterly pressure check & weight verification | PT Servochem Indonesia | Pass |
| 20 Feb 2025 | FM-SH-A | Refill | Agent refill setelah discharge test commissioning | PT Servochem Indonesia | Complete |
16
Total Channel
14
Channel Aktif
2
Channel Spare
0
Alarm Aktif
DI Card โ 16 Channel Status
Modul Digital Input ยท FACP InterfaceCH01
NORMAL
Fire Zone 1
CH02
NORMAL
Fire Zone 2
CH03
NORMAL
Fire Zone 3
CH04
NORMAL
Fire Zone 4
CH05
READY
FM-200 SH-A
CH06
READY
FM-200 SH-B
CH07
READY
FM-200 UPS-A
CH08
READY
FM-200 UPS-B
CH09
DRY
Water Leak 1
CH10
DRY
Water Leak 2
CH11
CLOSED
Door Zone A
CH12
CLOSED
Door Zone B
CH13
OPEN
Damper HVAC
CH14
STANDBY
Evac Bell
CH15
โ
Spare
CH16
โ
Spare
Konfigurasi Channel
| CH | Nama | Fungsi | Tipe Input | Logic | Kondisi Normal | Status |
|---|---|---|---|---|---|---|
| CH01 | Fire Zone 1 | FACP Zone Monitor | Dry Contact NO | Normal Open | Open / DRY | Normal |
| CH02 | Fire Zone 2 | FACP Zone Monitor | Dry Contact NO | Normal Open | Open / DRY | Normal |
| CH05 | FM-200 SH-A | Suppression Feedback | Dry Contact NC | Normal Close | Close / READY | Normal |
| CH09 | Water Leak 1 | Leak Detection | Resistive | Resistance >1kฮฉ | Dry (No Leak) | Normal |
| CH11 | Door Zone A | Access Control Interlock | Magnetic SW | Normally Closed | Closed | Normal |
| CH13 | Damper HVAC | Fire Damper Status | Dry Contact | Open = Normal | Open (Run) | Normal |
| CH15 | โ | Spare | โ | โ | โ | Spare |
| CH16 | โ | Spare | โ | โ | โ | Spare |
0
Real Alarm (YTD)
2
False Alarm (YTD)
4
Test / PM (YTD)
247
Hari Bebas Alarm
Statistik Event per Bulan
Log Event Lengkap
| Waktu | Zona | Sistem | Tipe | Keterangan | Durasi | Tindakan | Status |
|---|---|---|---|---|---|---|---|
| 2026-03-01 03:22 | Z08 - Storage | FACP | Trouble | Panel Trouble โ Detector Disconnect (1 unit) | Ongoing | Teknisi dinotifikasi | Open |
| 2026-02-20 14:15 | Z01 - SH-A | VESDA | Test | Authorized Test โ Aerosol commissioning VESDA-SH-A | 12 menit | Authorized, direset manual | Resolved |
| 2026-02-10 09:00 | All Zones | FACP | PM Test | Monthly Panel Self-Test โ Scheduled PM by Notifier | 5 menit | Scheduled, auto-reset | Resolved |
| 2026-01-28 19:42 | Z04 - UPS-A | FACP | False Alarm | False Alarm โ Dust particle dari aktivitas maintenance UPS | 3 menit | Investigasi + reset + bersihkan | Resolved |
| 2026-01-10 09:00 | All Zones | FACP | PM Test | Monthly Panel Self-Test | 5 menit | Scheduled, auto-reset | Resolved |
| 2025-12-15 22:11 | Z06 - Genset | FACP | False Alarm | False Alarm โ Asap knalpot genset saat test run bulanan | 7 menit | Investigasi + reset + prosedur diperketat | Resolved |